• Volume/Page
  • Keyword
  • DOI
  • Citation
  • Advanced
   
 
 
 

Flickr Twitter iResearch App Facebook

Year Range: 
Search Issue | RSS Feeds RSS
Previous Issue

Dec 1941

Volume 12, Issue 12, pp. 571-621


The Golden Eggs

G. P. H.

Rev. Sci. Instrum. 12, 571 (1941); http://dx.doi.org/10.1063/1.1769803 (2 pages)

Online Publication Date: 27 December 2004

Full Text: | Download PDF

Abstract Unavailable

The Importance of Scientific Instruments and Apparatus to the Teacher of Physics

Richard M. Sutton

Rev. Sci. Instrum. 12, 573 (1941); http://dx.doi.org/10.1063/1.1769804 (10 pages) | Cited 1 time

Online Publication Date: 27 December 2004

Full Text: | Download PDF

Abstract Unavailable

A Comparison Between a Geiger‐Mueller Counter, a Secondary Electron Multiplier Tube, and Photographic Film for Detecting Weak X‐Rays

A. Eisenstein and N. S. Gingrich

Rev. Sci. Instrum. 12, 582 (1941); http://dx.doi.org/10.1063/1.1769805 (5 pages) | Cited 8 times

Online Publication Date: 27 December 2004

Full Text: | Download PDF

Show Abstract
A comparison has been made between three methods, given in the title, for the detection of weak x‐rays. The secondary electron multiplier tube has a lower resolving time than the Geiger‐Mueller tube, but the G‐M tube is from 5 to 10 times as sensitive to x‐rays of the wave‐lengths here studied, 0.63A to 1.54A. A diffraction pattern of a liquid can be obtained with a G‐M counter in roughly one‐twentieth the time taken for a photographic exposure.

Developments in Ion Accelerating Tubes

J. H. Manley, L. J. Haworth, and E. A. Luebke

Rev. Sci. Instrum. 12, 587 (1941); http://dx.doi.org/10.1063/1.1769806 (4 pages) | Cited 3 times

Online Publication Date: 27 December 2004

Full Text: | Download PDF

Show Abstract
An artificial neutron source has been built which is very stable in operation and flexible in use. Using the D—D reaction, target currents of more than 200 microamperes at 300 kv give a neutron yield of 10 grams radium‐beryllium equivalent. It has been found that voltage stability at these currents may be greatly improved by the use of special diaphragms, and that a reflux target cooling system is very satisfactory in maintaining a heavy water‐ice target. Electrostatic deflection of the ion beam has produced a neutron source which may be modulated at high frequencies or otherwise time‐controlled.

An Apparatus for the Direct Determination of Slow Neutron Velocity Distributions

L. J. Haworth, J. H. Manley, and E. A. Luebke

Rev. Sci. Instrum. 12, 591 (1941); http://dx.doi.org/10.1063/1.1769807 (7 pages) | Cited 7 times

Online Publication Date: 27 December 2004

Full Text: | Download PDF

Show Abstract
Apparatus is described by means of which a modulated source of slow neutrons is produced and their intensity determined as a function of time. The deuteron beam of a high voltage tube is deflected by a modulated electrostatic field in such a way as to produce square bursts of fast neutrons of any desired length. After being slowed by hydrogenous material a selected beam of neutrons falls on a suitable detector at a measured distance from the source. Pulses from the detector are impressed on an oscilloscope screen, together with a sharply defined time scale and photographic records made. The time analysis of the neutron distribution is then made by a numerical count of the neutron pulses as a function of the time interval in which they occur.

A Photoelectric Star Counter

S. W. McCuskey and R. M. Scott

Rev. Sci. Instrum. 12, 597 (1941); http://dx.doi.org/10.1063/1.1769808 (5 pages) | Cited 1 time

Online Publication Date: 27 December 2004

Full Text: | Download PDF

Show Abstract
A new device which performs the photometry of stellar images on a photographic plate and which segregates the images according to size is described. The star images to be photometered are manually shifted into the optical focus of the device. The results of tests indicate greater accuracy in counting than is attainable by visual means. No systematic deviations of the counts so obtained from catalog compilations or from the results deduced visually were found.

Optimum Liquid Combinations for Cloud Chambers

Clifford Beck

Rev. Sci. Instrum. 12, 602 (1941); http://dx.doi.org/10.1063/1.1769809 (5 pages) | Cited 3 times

Online Publication Date: 27 December 2004

Full Text: | Download PDF

Show Abstract
A search was made for liquid mixtures giving low expansion ratio, low background fog, and good electron tracks in cloud chambers filled with air at near atmospheric pressure. As was expected from theory, mixtures of any lower alcohol with water gave a minimum in the curve of expansion ratio versus concentration, while no minimum was found in the curve for mixtures of any two alcohols. The optimum mixture found for chamber use was 50 percent ethyl or normal propyl alcohol, 25 percent water, and 25 percent acetone; the presence of acetone definitely increases the contrast between tracks and background fog. A brief study of photochemical fog, with a quartz mercury arc, showed that wave‐lengths below 3900A are chiefly responsible for such fog. Irradiation of pure alcohols gives no perceptible fog, but irradiation of the optimum mixture above produces dense fog. However the clean‐up after irradiation is sufficiently rapid to offset the disadvantage of its sensitivity to light.

A Speed Control for Sector Disks or Similar Equipment

R. H. Lee and L. R. Crisp

Rev. Sci. Instrum. 12, 607 (1941); http://dx.doi.org/10.1063/1.1769810 (2 pages)

Online Publication Date: 27 December 2004

Full Text: | Download PDF

Show Abstract
An apparatus is described by means of which the speed of a sector disk or other reasonably light equipment of similar nature may be accurately controlled and the speed read directly from a set of dials.

The Use of a McLeod Gauge in Measuring Small Volumes

N. B. Keevil, R. F. Errington, and L. T. Newman

Rev. Sci. Instrum. 12, 609 (1941); http://dx.doi.org/10.1063/1.1769811 (3 pages) | Cited 1 time

Online Publication Date: 27 December 2004

Full Text: | Download PDF

Show Abstract
Some precautions necessary for accurate measurements of volume with the McLeod gauge are discussed, particularly the necessity of determining the capillary depression from each set of readings. Applications to the determination of small quantities of helium are given.
back to top
RSS Feeds

Priority Rating

Rev. Sci. Instrum. 12, 611 (1941); http://dx.doi.org/10.1063/1.1769812 (1 page)

Online Publication Date: 27 December 2004

Full Text: | Download PDF

Abstract Unavailable
back to top
RSS Feeds

Layout Scheme for Plane Mirror Systems

Waldo H. Kliever

Rev. Sci. Instrum. 12, 612 (1941); http://dx.doi.org/10.1063/1.1769813 (1 page)

Online Publication Date: 27 December 2004

Full Text: | Download PDF

Abstract Unavailable

Note on the Doppler Effect

Charles G. McIlwraith

Rev. Sci. Instrum. 12, 612 (1941); http://dx.doi.org/10.1063/1.1769814 (1 page)

Online Publication Date: 27 December 2004

Full Text: | Download PDF

Abstract Unavailable

Preparation of Thin Potassium Foils

J. B. Platt and D. H. Tomboulian

Rev. Sci. Instrum. 12, 612 (1941); http://dx.doi.org/10.1063/1.1769815 (2 pages)

Online Publication Date: 27 December 2004

Full Text: | Download PDF

Abstract Unavailable
back to top
RSS Feeds
back to top New Instruments

New Instruments

Wm. F. Roeser

Rev. Sci. Instrum. 12, 613 (1941); http://dx.doi.org/10.1063/1.1769816 (5 pages)

Online Publication Date: 27 December 2004

Full Text: | Download PDF

Abstract Unavailable
back to top New Materials

New Materials

A. R. Olpin

Rev. Sci. Instrum. 12, 617 (1941); http://dx.doi.org/10.1063/1.1769817 (5 pages)

Online Publication Date: 27 December 2004

Full Text: | Download PDF

Abstract Unavailable
Close
Google Calendar
ADVERTISEMENT

close