The 20 articles with the most full-text downloads during the month, in descending order.


Invited Review Article: Laser vaporization cluster sources

Michael A. Duncan

Rev. Sci. Instrum. 83, 041101 (2012); http://dx.doi.org/10.1063/1.3697599 (19 pages)

Online Publication Date: 12 April 2012

Full Text: Read Online (HTML) | Download PDF

Show Abstract
The laser vaporization cluster source has been used for the production of gas phase atomic clusters and metal-molecular complexes for 30 years. Numerous experiments in the chemistry and physics of clusters have employed this source. Its operation is simple in principle, but there are many subtle design features that influence the number and size of clusters produced, as well as their composition, charge state, and temperature. This article examines all aspects of the design of these cluster sources, discussing the relevant chemistry, physics, and mechanical aspects of experimental configurations employed by different labs. The principles detailed here provide a framework for the design and implementation of this source for new applications.
Show PACS
42.60.By Design of specific laser systems
42.62.Eh Metrological applications; optical frequency synthesizers for precision spectroscopy
42.72.-g Optical sources and standards
36.40.-c Atomic and molecular clusters

Miniature active damping stage for scanning probe applications in ultra high vacuum

Maximilian Assig, Andreas Koch, Wolfgang Stiepany, Carola Straßer, Alexandra Ast, Klaus Kern, and Christian R. Ast

Rev. Sci. Instrum. 83, 033701 (2012); http://dx.doi.org/10.1063/1.3689769 (6 pages)

Online Publication Date: 2 March 2012

Full Text: Read Online (HTML) | Download PDF

Show Abstract
Scanning probe microscope (SPM) experiments demand a low vibration level to minimize the external influence on the measured signal. We present a miniature six-degree of freedom active damping stage based on a Gough-Stewart platform (hexapod) which is positioned in ultra high vacuum as close to the SPM as possible. In this way, vibrations originating from the experimental setup can be effectively reduced providing a quiet environment for the SPM. In addition, the hexapod provides a rigid reference point, which facilitates wiring as well as sample transfer. We outline the main working principle and show that for scanning tunneling microscopy (STM) measurements of a Si(111) 7 × 7 surface, the hexapod significantly improves the stability and quality of the topographic images.
Show PACS
07.79.Cz Scanning tunneling microscopes
68.37.Ef Scanning tunneling microscopy (including chemistry induced with STM)
06.30.Bp Spatial dimensions (e.g., position, lengths, volume, angles, and displacements)

Invited Review Article: Single-photon sources and detectors

M. D. Eisaman, J. Fan, A. Migdall, and S. V. Polyakov

Rev. Sci. Instrum. 82, 071101 (2011); http://dx.doi.org/10.1063/1.3610677 (25 pages)

Online Publication Date: 27 July 2011

Full Text: Read Online (HTML) | Download PDF

Show Abstract
We review the current status of single-photon-source and single-photon-detector technologies operating at wavelengths from the ultraviolet to the infrared. We discuss applications of these technologies to quantum communication, a field currently driving much of the development of single-photon sources and detectors.
Show PACS
03.67.Hk Quantum communication
85.60.Gz Photodetectors (including infrared and CCD detectors)

WSXM: A software for scanning probe microscopy and a tool for nanotechnology

I. Horcas, R. Fernández, J. M. Gómez-Rodríguez, J. Colchero, J. Gómez-Herrero, and A. M. Baro

Rev. Sci. Instrum. 78, 013705 (2007); http://dx.doi.org/10.1063/1.2432410 (8 pages)

Online Publication Date: 31 January 2007

Full Text: Read Online (HTML) | Download PDF

Show Abstract
In this work we briefly describe the most relevant features of WSXM, a freeware scanning probe microscopy software based on MS-Windows. The article is structured in three different sections: The introduction is a perspective on the importance of software on scanning probe microscopy. The second section is devoted to describe the general structure of the application; in this section the capabilities of WSXM to read third party files are stressed. Finally, a detailed discussion of some relevant procedures of the software is carried out.
Show PACS
07.79.Cz Scanning tunneling microscopes

Detection of nanosecond-scale, high power THz pulses with a field effect transistor

S. Preu, H. Lu, M. S. Sherwin, and A. C. Gossard

Rev. Sci. Instrum. 83, 053101 (2012); http://dx.doi.org/10.1063/1.4705986 (6 pages)

Online Publication Date: 1 May 2012

Full Text: Read Online (HTML) | Download PDF

Show Abstract
We demonstrate detection and resolution of high power, 34 ns free electron laser pulses using a rectifying field effect transistor. The detector remains linear up to an input power of 11 ± 0.5 W at a pulse energy of 20 ± 1 μJ at 240 GHz. We compare its performance to a protected Schottky diode, finding a shorter intrinsic time constant. The damage threshold is estimated to be a few 100 W. The detector is, therefore, well-suited for characterizing high power THz pulses. We further demonstrate that the same detector can be used to detect low power continuous-wave THz signals with a post detection limited noise floor of 3.1 μW/math. Such ultrafast, high power detectors are important tools for high power and high energy THz facilities such as free electron lasers.
Show PACS
41.60.Cr Free-electron lasers
42.60.-v Laser optical systems: design and operation

Thermal conductivity measurement from 30 to 750 K: the 3ω method

David G. Cahill

Rev. Sci. Instrum. 61, 802 (1990); http://dx.doi.org/10.1063/1.1141498 (7 pages)

Full Text: | Download PDF

Show Abstract
An ac technique for measuring the thermal conductivity of dielectric solids between 30 and 750 K is described. This technique, the 3ω method, can be applied to bulk amorphous solids and crystals as well as amorphous films tens of microns thick. Errors from black‐body radiation are calculated to be less than 2% even at 1000 K. Data for a‐SiO2, Pyrex 7740, and Pyroceram 9606 are compared to results obtained by conventional techniques.
Show PACS
07.20.-n Thermal instruments and apparatus
66.70.-f Nonelectronic thermal conduction and heat-pulse propagation in solids; thermal waves

Retrofitting an atomic force microscope with photothermal excitation for a clean cantilever response in low Q environments

Aleksander Labuda, Kei Kobayashi, Yoichi Miyahara, and Peter Grütter

Rev. Sci. Instrum. 83, 053703 (2012); http://dx.doi.org/10.1063/1.4712286 (8 pages)

Online Publication Date: 10 May 2012

Full Text: Read Online (HTML) | Download PDF

Show Abstract
It is well known that the low-Q regime in dynamic atomic force microscopy is afflicted by instrumental artifacts (known as “the forest of peaks”) caused by piezoacoustic excitation of the cantilever. In this article, we unveil additional issues associated with piezoacoustic excitation that become apparent and problematic at low Q values. We present the design of a photothermal excitation system that resolves these issues, and demonstrate its performance on force spectroscopy at the interface of gold and an ionic liquid with an overdamped cantilever (Q < 0.5). Finally, challenges in the interpretation of low-Q dynamic AFM measurements are discussed.
Show PACS
07.79.Lh Atomic force microscopes

Femtosecond pulse shaping using spatial light modulators

A. M. Weiner

Rev. Sci. Instrum. 71, 1929 (2000); http://dx.doi.org/10.1063/1.1150614 (32 pages)

Full Text: | Download PDF

Show Abstract
We review the field of femtosecond pulse shaping, in which Fourier synthesis methods are used to generate nearly arbitrarily shaped ultrafast optical wave forms according to user specification. An emphasis is placed on programmable pulse shaping methods based on the use of spatial light modulators. After outlining the fundamental principles of pulse shaping, we then present a detailed discussion of pulse shaping using several different types of spatial light modulators. Finally, new research directions in pulse shaping, and applications of pulse shaping to optical communications, biomedical optical imaging, high power laser amplifiers, quantum control, and laser-electron beam interactions are reviewed. © 2000 American Institute of Physics.
Show PACS
42.65.Re Ultrafast processes; optical pulse generation and pulse compression
42.79.Hp Optical processors, correlators, and modulators
01.30.Rr Surveys and tutorial papers; resource letters
42.60.Fc Modulation, tuning, and mode locking

High passive-stability diode-laser design for use in atomic-physics experiments

Eryn C. Cook, Paul J. Martin, Tobias L. Brown-Heft, Jeffrey C. Garman, and Daniel A. Steck

Rev. Sci. Instrum. 83, 043101 (2012); http://dx.doi.org/10.1063/1.3698003 (9 pages)

Online Publication Date: 4 April 2012

Full Text: Read Online (HTML) | Download PDF

Show Abstract
We present the design and performance characterization of an external-cavity diode-laser system optimized for high stability, low passive spectral linewidth, low cost, and ease of in-house assembly. The main cavity body is machined from a single aluminum block for robustness to temperature changes and mechanical vibrations, and features a stiff and light diffraction-grating arm to suppress low-frequency mechanical resonances. The cavity is vacuum sealed, and a custom-molded silicone external housing further isolates the system from acoustic noise and temperature fluctuations. Beam shaping, optical isolation, and fiber coupling are integrated, and the design is easily adapted to many commonly used wavelengths. Resonance data, passive-linewidth data, and passive stability characterization of the new design demonstrate that its performance exceeds published specifications for commercial precision diode-laser systems. The design is fully documented and freely available.
Show PACS
42.55.Px Semiconductor lasers; laser diodes
42.60.By Design of specific laser systems
42.60.Da Resonators, cavities, amplifiers, arrays, and rings
42.65.Re Ultrafast processes; optical pulse generation and pulse compression

Ultrafast optical parametric amplifiers

Giulio Cerullo and Sandro De Silvestri

Rev. Sci. Instrum. 74, 1 (2003); http://dx.doi.org/10.1063/1.1523642 (18 pages)

Online Publication Date: 16 January 2003

Full Text: | Download PDF

Show Abstract
Over the last decade there have been spectacular developments in ultrafast laser technology, due to the introduction of solid state active materials and of new mode-locking and amplification techniques. These advances, together with the discovery of new nonlinear optical crystals, have fostered the introduction of ultrafast optical parametric amplifiers as a practical source of femtosecond pulses tunable across the visible and infrared spectral ranges. This article summarizes the recent progress in the development of ultrafast optical parametric amplifiers, giving the basic design principles for different frequency ranges and in addition presenting some advanced designs for the generation of ultrabroadband, few-optical-cycle pulses. Finally, we also briefly discuss the possibility of applying parametric amplification schemes to large-scale, petawatt-level systems. © 2003 American Institute of Physics.
Show PACS
42.65.Re Ultrafast processes; optical pulse generation and pulse compression
42.65.Yj Optical parametric oscillators and amplifiers
42.60.Fc Modulation, tuning, and mode locking

Optical trapping

Keir C. Neuman and Steven M. Block

Rev. Sci. Instrum. 75, 2787 (2004); http://dx.doi.org/10.1063/1.1785844 (23 pages)

Online Publication Date: 2 September 2004

Full Text: | Download PDF

Show Abstract
Since their invention just over 20 years ago, optical traps have emerged as a powerful tool with broad-reaching applications in biology and physics. Capabilities have evolved from simple manipulation to the application of calibrated forces on—and the measurement of nanometer-level displacements of—optically trapped objects. We review progress in the development of optical trapping apparatus, including instrument design considerations, position detection schemes and calibration techniques, with an emphasis on recent advances. We conclude with a brief summary of innovative optical trapping configurations and applications.
Show PACS
37.10.Vz Mechanical effects of light on atoms, molecules, and ions
06.30.Bp Spatial dimensions (e.g., position, lengths, volume, angles, and displacements)
01.30.Rr Surveys and tutorial papers; resource letters
06.20.F- Units and standards
87.80.Cc Optical trapping

Photoacoustic imaging in biomedicine

Minghua Xu and Lihong V. Wang

Rev. Sci. Instrum. 77, 041101 (2006); http://dx.doi.org/10.1063/1.2195024 (22 pages)

Online Publication Date: 17 April 2006

Full Text: Read Online (HTML) | Download PDF

Show Abstract
Photoacoustic imaging (also called optoacoustic or thermoacoustic imaging) has the potential to image animal or human organs, such as the breast and the brain, with simultaneous high contrast and high spatial resolution. This article provides an overview of the rapidly expanding field of photoacoustic imaging for biomedical applications. Imaging techniques, including depth profiling in layered media, scanning tomography with focused ultrasonic transducers, image forming with an acoustic lens, and computed tomography with unfocused transducers, are introduced. Special emphasis is placed on computed tomography, including reconstruction algorithms, spatial resolution, and related recent experiments. Promising biomedical applications are discussed throughout the text, including (1) tomographic imaging of the skin and other superficial organs by laser-induced photoacoustic microscopy, which offers the critical advantages, over current high-resolution optical imaging modalities, of deeper imaging depth and higher absorption contrasts, (2) breast cancer detection by near-infrared light or radio-frequency–wave-induced photoacoustic imaging, which has important potential for early detection, and (3) small animal imaging by laser-induced photoacoustic imaging, which measures unique optical absorption contrasts related to important biochemical information and provides better resolution in deep tissues than optical imaging.
Show PACS
87.63.L- Visual imaging
87.63.D- Ultrasonography
87.63.Hg Thermography
87.57.N- Image analysis
87.57.C- Image quality
42.62.Be Biological and medical applications

A nanopositioner for scanning probe microscopy: The KoalaDrive

Vasily Cherepanov, Peter Coenen, and Bert Voigtländer

Rev. Sci. Instrum. 83, 023703 (2012); http://dx.doi.org/10.1063/1.3681444 (4 pages)

Online Publication Date: 7 February 2012

Full Text: Read Online (HTML) | Download PDF

Show Abstract
We present a new type of piezoelectric nanopositioner called KoalaDrive which can have a diameter less than 2.5 mm and a length smaller than 10 mm. The new operating principle provides a smooth travel sequence and avoids shaking which is intrinsic to nanopositioners based on inertial motion with sawtooth driving signals. In scanning probe microscopy, the KoalaDrive can be used for the coarse approach of the tip or sensor towards the sample. Inserting the KoalaDrive in a piezo tube for xyz-scanning integrates a complete scanning tunneling microscope (STM) inside a 4 mm outer diameter piezo tube of <10 mm length. The use of the KoalaDrive makes the scanning probe microscopy design ultracompact and accordingly leads to a high mechanical stability. The drive is UHV, low temperature, and magnetic field compatible. The compactness of the KoalaDrive allows building a multi-tip STM as small as a single tip STM.
Show PACS
07.79.Cz Scanning tunneling microscopes
06.60.Sx Positioning and alignment; manipulating, remote handling
68.37.Ef Scanning tunneling microscopy (including chemistry induced with STM)

A method to provide rapid in situ determination of tip radius in dynamic atomic force microscopy

Sergio Santos, Li Guang, Tewfik Souier, Karim Gadelrab, Matteo Chiesa, and Neil H. Thomson

Rev. Sci. Instrum. 83, 043707 (2012); http://dx.doi.org/10.1063/1.4704376 (11 pages)

Online Publication Date: 24 April 2012

Full Text: Read Online (HTML) | Download PDF

Show Abstract
We provide a method to characterize the tip radius of an atomic force microscopy in situ by monitoring the dynamics of the cantilever in ambient conditions. The key concept is that the value of free amplitude for which transitions from the attractive to repulsive force regimes are observed, strongly depends on the curvature of the tip. In practice, the smaller the value of free amplitude required to observe a transition, the sharper the tip. This general behavior is remarkably independent of the properties of the sample and cantilever characteristics and shows the strong dependence of the transitions on the tip radius. The main advantage of this method is rapid in situ characterization. Rapid in situ characterization enables one to continuously monitor the tip size during experiments. Further, we show how to reproducibly shape the tip from a given initial size to any chosen larger size. This approach combined with the in situ tip size monitoring enables quantitative comparison of materials measurements between samples. These methods are set to allow quantitative data acquisition and make direct data comparison readily available in the community.
Show PACS
06.30.Bp Spatial dimensions (e.g., position, lengths, volume, angles, and displacements)
07.79.Lh Atomic force microscopes

Calibration of atomic‐force microscope tips

Jeffrey L. Hutter and John Bechhoefer

Rev. Sci. Instrum. 64, 1868 (1993); http://dx.doi.org/10.1063/1.1143970 (6 pages)

Full Text: | Download PDF

Show Abstract
Images and force measurements taken by an atomic‐force microscope (AFM) depend greatly on the properties of the spring and tip used to probe the sample’s surface. In this article, we describe a simple, nondestructive procedure for measuring the force constant, resonant frequency, and quality factor of an AFM cantilever spring and the effective radius of curvature of an AFM tip. Our procedure uses the AFM itself and does not require additional equipment.
Show PACS
68.37.Ef Scanning tunneling microscopy (including chemistry induced with STM)
68.37.Ps Atomic force microscopy (AFM)
68.37.Rt Magnetic force microscopy (MFM)
68.37.Uv Near-field scanning microscopy and spectroscopy
87.64.Dz Scanning tunneling and atomic force microscopy

Nanoelectromechanical systems

K. L. Ekinci and M. L. Roukes

Rev. Sci. Instrum. 76, 061101 (2005); http://dx.doi.org/10.1063/1.1927327 (12 pages)

Online Publication Date: 26 May 2005

Full Text: Read Online (HTML) | Download PDF

Show Abstract
Nanoelectromechanical systems (NEMS) are drawing interest from both technical and scientific communities. These are electromechanical systems, much like microelectromechanical systems, mostly operated in their resonant modes with dimensions in the deep submicron. In this size regime, they come with extremely high fundamental resonance frequencies, diminished active masses,and tolerable force constants; the quality (Q) factors of resonance are in the range Q ∼ 103–105—significantly higher than those of electrical resonant circuits. These attributes collectively make NEMS suitable for a multitude of technological applications such as ultrafast sensors, actuators, and signal processing components. Experimentally, NEMS are expected to open up investigations of phonon mediated mechanical processes and of the quantum behavior of mesoscopic mechanical systems. However, there still exist fundamental and technological challenges to NEMS optimization. In this review we shall provide a balanced introduction to NEMS by discussing the prospects and challenges in this rapidly developing field and outline an exciting emerging application, nanoelectromechanical mass detection.
Show PACS
85.85.+j Micro- and nano-electromechanical systems (MEMS/NEMS) and devices
85.35.-p Nanoelectronic devices

Atom probe tomography

Thomas F. Kelly and Michael K. Miller

Rev. Sci. Instrum. 78, 031101 (2007); http://dx.doi.org/10.1063/1.2709758 (20 pages)

Online Publication Date: 30 March 2007

Full Text: Read Online (HTML) | Download PDF

Show Abstract
The technique of atom probe tomography (APT) is reviewed with an emphasis on illustrating what is possible with the technique both now and in the future. APT delivers the highest spatial resolution (sub-0.3-nm) three-dimensional compositional information of any microscopy technique. Recently, APT has changed dramatically with new hardware configurations that greatly simplify the technique and improve the rate of data acquisition. In addition, new methods have been developed to fabricate suitable specimens from new classes of materials. Applications of APT have expanded from structural metals and alloys to thin multilayer films on planar substrates, dielectric films, semiconducting structures and devices, and ceramic materials. This trend toward a broader range of materials and applications is likely to continue.
Show PACS
07.78.+s Electron, positron, and ion microscopes; electron diffractometers
42.30.Wb Image reconstruction; tomography

Time‐of‐Flight Mass Spectrometer with Improved Resolution

W. C. Wiley and I. H. McLaren

Rev. Sci. Instrum. 26, 1150 (1955); http://dx.doi.org/10.1063/1.1715212 (8 pages)

Online Publication Date: 29 December 2004

Full Text: | Download PDF

Show Abstract
A new type of ion gun is described which greatly improves the resolution of a nonmagnetic time‐of‐flight mass spectrometer. The focusing action of this gun is discussed and analyzed mathematically. The validity of the analysis and the practicability of the gun are demonstrated by the spectra obtained. The spectrometer is capable of measuring the relative abundance of adjacent masses well beyond 100 amu.

Velocity map imaging of ions and electrons using electrostatic lenses: Application in photoelectron and photofragment ion imaging of molecular oxygen

André T. J. B. Eppink and David H. Parker

Rev. Sci. Instrum. 68, 3477 (1997); http://dx.doi.org/10.1063/1.1148310 (8 pages)

Full Text: | Download PDF

Show Abstract
The application of electrostatic lenses is demonstrated to give a substantial improvement of the two-dimensional (2D) ion/electron imaging technique. This combination of ion lens optics and 2D detection makes “velocity map imaging” possible, i.e., all particles with the same initial velocity vector are mapped onto the same point on the detector. Whereas the more common application of grid electrodes leads to transmission reduction, severe trajectory deflections and blurring due to the non-point source geometry, these problems are avoided with open lens electrodes. A three-plate assembly with aperture electrodes has been tested and its properties are compared with those of grid electrodes. The photodissociation processes occurring in molecular oxygen following the two-photon 3dπ(3Σ1g)(v = 2, N = 2)←X(3Σg) Rydberg excitation around 225 nm are presented here to show the improvement in spatial resolution in the ion and electron images. Simulated trajectory calculations show good agreement with experiment and support the appealing properties of this velocity mapping technique. © 1997 American Institute of Physics.
Show PACS
41.85.Ne Electrostatic lenses, septa
33.80.Gj Diffuse spectra; predissociation, photodissociation
33.60.+q Photoelectron spectra
33.80.Rv Multiphoton ionization and excitation to highly excited states (e.g., Rydberg states)

Modified Spin‐Echo Method for Measuring Nuclear Relaxation Times

S. Meiboom and D. Gill

Rev. Sci. Instrum. 29, 688 (1958); http://dx.doi.org/10.1063/1.1716296 (4 pages)

Online Publication Date: 29 December 2004

Full Text: | Download PDF

Show Abstract
A spin echo method adapted to the measurement of long nuclear relaxation times (T2) in liquids is described. The pulse sequence is identical to the one proposed by Carr and Purcell, but the rf of the successive pulses is coherent, and a phase shift of 90° is introduced in the first pulse. Very long T2 values can be measured without appreciable effect of diffusion.