Top 20 Most Read Articles

May 2010

The 20 articles with the most full-text downloads during the month, in descending order.


High sensitivity magnetic imaging using an array of spins in diamond

S. Steinert, F. Dolde, P. Neumann, A. Aird, B. Naydenov, G. Balasubramanian, F. Jelezko, and J. Wrachtrup

Rev. Sci. Instrum. 81, 043705 (2010); http://dx.doi.org/10.1063/1.3385689 (5 pages)

Online Publication Date: 23 April 2010

Full Text: Read Online (HTML) | Download PDF

Show Abstract
We present a solid state magnetic field imaging technique using a two-dimensional array of spins in diamond. The magnetic sensing spin array is made of nitrogen vacancy (NV) centers created at shallow depths. Their optical response is used for measuring external magnetic fields in close proximity. Optically detected magnetic resonance is read out from a 60×60 μm2 field of view in a multiplexed manner using a charge coupled device camera. We experimentally demonstrate full two-dimensional vector imaging of the magnetic field produced by a pair of current carrying microwires. The presented wide-field NV magnetometer offers, in addition to its high magnetic sensitivity and vector reconstruction, an unprecedented spatiotemporal resolution and functionality at room temperature.
Show PACS
85.75.Ss Magnetic field sensors using spin polarized transport
61.72.jd Vacancies
07.07.Df Sensors (chemical, optical, electrical, movement, gas, etc.); remote sensing
42.79.Pw Imaging detectors and sensors
02.10.Ud Linear algebra
07.55.Ge Magnetometers for magnetic field measurements

Wavelength stabilization of a synchronously pumped optical parametric oscillator: Optimizing proportional-integral control

Tobias P. Lamour, Jinghua Sun, and Derryck T. Reid

Rev. Sci. Instrum. 81, 053101 (2010); http://dx.doi.org/10.1063/1.3385684 (6 pages)

Online Publication Date: 3 May 2010

Full Text: Read Online (HTML) | Download PDF

Show Abstract
We describe a formal approach to the wavelength stabilization of a synchronously pumped ultrafast optical parametric oscillator using proportional-integral feedback control. Closed-loop wavelength stabilization was implemented by using a position-sensitive detector as a sensor and a piezoelectric transducer to modify the cavity length of the oscillator. By characterizing the frequency response of the loop components, we constructed a predictive model of the controller which showed formally that a proportional-only feedback was insufficient to eliminate the steady state error, consistent with experimental observations. The optimal proportional and integral gain coefficients were obtained from a numerical optimization of the controller model that minimized the settling time while also limiting the overshoot to an acceptable value. Results are presented showing effective wavelength and power stabilization to levels limited only by the relative intensity noise of the pump laser.
Show PACS
42.65.Yj Optical parametric oscillators and amplifiers
07.05.Dz Control systems

WSXM: A software for scanning probe microscopy and a tool for nanotechnology

I. Horcas, R. Fernández, J. M. Gómez-Rodríguez, J. Colchero, J. Gómez-Herrero, and A. M. Baro

Rev. Sci. Instrum. 78, 013705 (2007); http://dx.doi.org/10.1063/1.2432410 (8 pages)

Online Publication Date: 31 January 2007

Full Text: Read Online (HTML) | Download PDF

Show Abstract
In this work we briefly describe the most relevant features of WSXM, a freeware scanning probe microscopy software based on MS-Windows. The article is structured in three different sections: The introduction is a perspective on the importance of software on scanning probe microscopy. The second section is devoted to describe the general structure of the application; in this section the capabilities of WSXM to read third party files are stressed. Finally, a detailed discussion of some relevant procedures of the software is carried out.
Show PACS
07.79.Cz Scanning tunneling microscopes

Invited Article: High-pressure techniques for condensed matter physics at low temperature

Yejun Feng, R. Jaramillo, Jiyang Wang, Yang Ren, and T. F. Rosenbaum

Rev. Sci. Instrum. 81, 041301 (2010); http://dx.doi.org/10.1063/1.3400212 (8 pages)

Online Publication Date: 20 April 2010

Full Text: Read Online (HTML) | Download PDF

Show Abstract
Condensed matter experiments at high pressure accentuate the need for accurate pressure scales over a broad range of temperatures, as well as placing a premium on a homogeneous pressure environment. However, challenges remain in diamond anvil cell technology, including both the quality of various pressure transmitting media and the accuracy of secondary pressure scales at low temperature. We directly calibrate the ruby fluorescence R1 line shift with pressure at T = 4.5 K using high-resolution x-ray powder diffraction measurements of the silver lattice constant and its known equation of state up to P = 16 GPa. Our results reveal a ruby pressure scale at low temperatures that differs by 6% from the best available ruby scale at room T. We also use ruby fluorescence to characterize the pressure inhomogeneity and anisotropy in two representative and commonly used pressure media, helium and methanol:ethanol 4:1, under the same preparation conditions for pressures up to 20 GPa at T = 5 K. Contrary to the accepted wisdom, both media show equal levels of pressure inhomogeneity measured over the same area, with a consistent ΔP/P per unit area of ±1.8 %/(104μm2) from 0 to 20 GPa. The helium medium shows an essentially constant deviatoric stress of 0.021±0.011 GPa up to 16 GPa, while the methanol:ethanol mixture shows a similar level of anisotropy up to 10 GPa, above which the anisotropy increases. The quality of both pressure media is further examined under the more stringent requirements of single crystal x-ray diffraction at cryogenic temperature. For such experiments we conclude that the ratio of sample-to-pressure chamber volume is a critical parameter in maintaining sample quality at high pressure, and may affect the choice of pressure medium.
Show PACS
62.50.-p High-pressure effects in solids and liquids
81.40.Vw Pressure treatment
78.60.-b Other luminescence and radiative recombination

MEMS-based high speed scanning probe microscopy

E. C. M. Disseldorp, F. C. Tabak, A. J. Katan, M. B. S. Hesselberth, T. H. Oosterkamp, J. W. M. Frenken, and W. M. van Spengen

Rev. Sci. Instrum. 81, 043702 (2010); http://dx.doi.org/10.1063/1.3361215 (7 pages)

Online Publication Date: 12 April 2010

Full Text: Read Online (HTML) | Download PDF

Show Abstract
The high speed performance of a scanning probe microscope (SPM) is improved if a microelectromechanical systems (MEMS) device is employed for the out-of-plane scanning motion. We have carried out experiments with MEMS high-speed z-scanners (189 kHz fundamental resonance frequency) in both atomic force microscope and scanning tunneling microscope modes. The experiments show that with the current MEMS z-scanner, lateral tip speeds of 5 mm/s can be achieved with full feedback on surfaces with significant roughness. The improvement in scan speed, obtained with MEMS scanners, increases the possibilities for SPM observations of dynamic processes. Even higher speed MEMS scanners with fundamental resonance frequencies in excess of a megahertz are currently under development.
Show PACS
07.79.Cz Scanning tunneling microscopes
07.79.Lh Atomic force microscopes
07.10.Cm Micromechanical devices and systems

Atom probe tomography

Thomas F. Kelly and Michael K. Miller

Rev. Sci. Instrum. 78, 031101 (2007); http://dx.doi.org/10.1063/1.2709758 (20 pages)

Online Publication Date: 30 March 2007

Full Text: Read Online (HTML) | Download PDF

Show Abstract
The technique of atom probe tomography (APT) is reviewed with an emphasis on illustrating what is possible with the technique both now and in the future. APT delivers the highest spatial resolution (sub-0.3-nm) three-dimensional compositional information of any microscopy technique. Recently, APT has changed dramatically with new hardware configurations that greatly simplify the technique and improve the rate of data acquisition. In addition, new methods have been developed to fabricate suitable specimens from new classes of materials. Applications of APT have expanded from structural metals and alloys to thin multilayer films on planar substrates, dielectric films, semiconducting structures and devices, and ceramic materials. This trend toward a broader range of materials and applications is likely to continue.
Show PACS
07.78.+s Electron, positron, and ion microscopes; electron diffractometers
42.30.Wb Image reconstruction; tomography

Optical trapping

Keir C. Neuman and Steven M. Block

Rev. Sci. Instrum. 75, 2787 (2004); http://dx.doi.org/10.1063/1.1785844 (23 pages)

Online Publication Date: 2 September 2004

Full Text: | Download PDF

Show Abstract
Since their invention just over 20 years ago, optical traps have emerged as a powerful tool with broad-reaching applications in biology and physics. Capabilities have evolved from simple manipulation to the application of calibrated forces on—and the measurement of nanometer-level displacements of—optically trapped objects. We review progress in the development of optical trapping apparatus, including instrument design considerations, position detection schemes and calibration techniques, with an emphasis on recent advances. We conclude with a brief summary of innovative optical trapping configurations and applications.
Show PACS
37.10.Vz Mechanical effects of light on atoms, molecules, and ions
06.30.Bp Spatial dimensions (e.g., position, lengths, volume, angles, and displacements)
01.30.Rr Surveys and tutorial papers; resource letters
06.20.F- Units and standards
87.80.Cc Optical trapping

Optical sensing and determination of complex reflection coefficients of plasmonic structures using transmission interferometric plasmonic sensor

Takumi Sannomiya, Tobias E. Balmer, Christian Hafner, Manfred Heuberger, and Janos Vörös

Rev. Sci. Instrum. 81, 053102 (2010); http://dx.doi.org/10.1063/1.3405912 (9 pages)

Online Publication Date: 6 May 2010

Full Text: Read Online (HTML) | Download PDF

Show Abstract
The combination of interferometry and plasmonic structure, which consists of gold nanoparticle layer, sputter coated silicon oxide spacer layer, and aluminum mirror layer, was studied in transmission mode for biosensing and refractive index sensing applications. Because of the interferometric nature of the system, the information of the reflection amplitude and phase of the plasmonic layer can be deduced from one spectrum. The modulation amplitude in the transmission spectrum, caused by the interference between the plasmonic particle layer and the mirror layer, increases upon the refractive index increase around the plasmonic particles due to their coherent backscattering property. Our proposed evaluation method requires only two light sources with different wavelengths for a stable self-referenced signal, which can be easily and precisely tuned by a transparent spacer layer thickness. Unlike the standard localized surface plasmon sensors, where a sharp resonance peak is essential, a broad band plasmon resonance is accepted in this method. This leads to large fabrication tolerance of the plasmonic structures. We investigated bulk and adsorption layer sensitivities both experimentally and by simulation. The highest sensitivity wavelength corresponded to the resonance of the plasmonic particles, but useful signals are produced in a much broader spectral range. Analysis of a single transmission spectrum allowed us to access the wavelength-dependent complex reflection coefficient of the plasmonic particle layer, which confirmed the reflection amplitude increase in the plasmonic particle layer upon molecular adsorption.
Show PACS
07.07.Df Sensors (chemical, optical, electrical, movement, gas, etc.); remote sensing
07.60.Ly Interferometers
42.25.-p Wave optics

Time‐of‐Flight Mass Spectrometer with Improved Resolution

W. C. Wiley and I. H. McLaren

Rev. Sci. Instrum. 26, 1150 (1955); http://dx.doi.org/10.1063/1.1715212 (8 pages)

Online Publication Date: 29 December 2004

Full Text: | Download PDF

Show Abstract
A new type of ion gun is described which greatly improves the resolution of a nonmagnetic time‐of‐flight mass spectrometer. The focusing action of this gun is discussed and analyzed mathematically. The validity of the analysis and the practicability of the gun are demonstrated by the spectra obtained. The spectrometer is capable of measuring the relative abundance of adjacent masses well beyond 100 amu.

A tunable radio-frequency magnetic probe

B. Sun, G. Y. Yuan, W. G. Huo, and Z. F. Ding

Rev. Sci. Instrum. 81, 054703 (2010); http://dx.doi.org/10.1063/1.3402288 (8 pages)

Online Publication Date: 7 May 2010

Full Text: Read Online (HTML) | Download PDF

Show Abstract
A tunable center-tapped transformer is proposed to increase the output of a rf magnetic probe and improve the signal-to-noise ratio. The tuning is implemented by a variable capacitor connected parallel with the primary winding of the tunable center-tapped transformer. Undesirable common-to-differential conversion is reduced by installing a compensating capacitor. In addition, a planar Faraday shield is installed between the windings of the transformer to further suppress the electrostatic coupling. It is found that tuning the variable capacitor can result in a resonance in the output voltage of the rf magnetic probe. The largest output voltage, achieved with the tunable magnetic probe under the optimal condition, is higher than that with a conventional one by an order of magnitude. Effects of the compensating capacitance on the common-mode output voltage are studied and discussed. Influences of parameters such as cable length, the coupling coefficient, and the step-up ratio of the transformer on the output voltage are also presented. Analytical derivations and numerical calculations based on the equivalent circuit are performed to elucidate the characteristics of the differential mode.
Show PACS
84.70.+p High-current and high-voltage technology: power systems; power transmission lines and cables

Thermal conductivity measurement from 30 to 750 K: the 3ω method

David G. Cahill

Rev. Sci. Instrum. 61, 802 (1990); http://dx.doi.org/10.1063/1.1141498 (7 pages)

Full Text: | Download PDF

Show Abstract
An ac technique for measuring the thermal conductivity of dielectric solids between 30 and 750 K is described. This technique, the 3ω method, can be applied to bulk amorphous solids and crystals as well as amorphous films tens of microns thick. Errors from black‐body radiation are calculated to be less than 2% even at 1000 K. Data for a‐SiO2, Pyrex 7740, and Pyroceram 9606 are compared to results obtained by conventional techniques.
Show PACS
07.20.-n Thermal instruments and apparatus
66.70.-f Nonelectronic thermal conduction and heat-pulse propagation in solids; thermal waves

Nanoelectromechanical systems

K. L. Ekinci and M. L. Roukes

Rev. Sci. Instrum. 76, 061101 (2005); http://dx.doi.org/10.1063/1.1927327 (12 pages)

Online Publication Date: 26 May 2005

Full Text: Read Online (HTML) | Download PDF

Show Abstract
Nanoelectromechanical systems (NEMS) are drawing interest from both technical and scientific communities. These are electromechanical systems, much like microelectromechanical systems, mostly operated in their resonant modes with dimensions in the deep submicron. In this size regime, they come with extremely high fundamental resonance frequencies, diminished active masses,and tolerable force constants; the quality (Q) factors of resonance are in the range Q ∼ 103–105—significantly higher than those of electrical resonant circuits. These attributes collectively make NEMS suitable for a multitude of technological applications such as ultrafast sensors, actuators, and signal processing components. Experimentally, NEMS are expected to open up investigations of phonon mediated mechanical processes and of the quantum behavior of mesoscopic mechanical systems. However, there still exist fundamental and technological challenges to NEMS optimization. In this review we shall provide a balanced introduction to NEMS by discussing the prospects and challenges in this rapidly developing field and outline an exciting emerging application, nanoelectromechanical mass detection.
Show PACS
85.85.+j Micro- and nano-electromechanical systems (MEMS/NEMS) and devices
85.35.-p Nanoelectronic devices

Surface magneto-optic Kerr effect

Z. Q. Qiu and S. D. Bader

Rev. Sci. Instrum. 71, 1243 (2000); http://dx.doi.org/10.1063/1.1150496 (13 pages)

Full Text: | Download PDF

Show Abstract
The surface magneto-optic Kerr effect (SMOKE) has significantly impacted research on magnetic thin films. This is due to its sensitivity, local probing nature, and experimental simplicity. The polar and longitudinal Kerr effects are characterized by a complex rotation of the plane of polarization of linearly polarized incident light upon reflection from the surface of a ferromagnetic material. The rotation is directly related to the magnetization of the material within the probing region of the light. Light penetrates into metals >20 nm deep, but the SMOKE technique derives its surface sensitivity from the limited thickness of the deposited magnetic film, which can be as thin as one atomic layer. Basic principles, experimental arrangements, and applications of SMOKE are reviewed in order to acquaint the nonspecialist with the technique and place it into perspective. © 2000 American Institute of Physics.
Show PACS
78.20.Ls Magneto-optical effects
75.70.-i Magnetic properties of thin films, surfaces, and interfaces
75.70.Rf Surface magnetism
01.30.Rr Surveys and tutorial papers; resource letters

Photoacoustic imaging in biomedicine

Minghua Xu and Lihong V. Wang

Rev. Sci. Instrum. 77, 041101 (2006); http://dx.doi.org/10.1063/1.2195024 (22 pages)

Online Publication Date: 17 April 2006

Full Text: Read Online (HTML) | Download PDF

Show Abstract
Photoacoustic imaging (also called optoacoustic or thermoacoustic imaging) has the potential to image animal or human organs, such as the breast and the brain, with simultaneous high contrast and high spatial resolution. This article provides an overview of the rapidly expanding field of photoacoustic imaging for biomedical applications. Imaging techniques, including depth profiling in layered media, scanning tomography with focused ultrasonic transducers, image forming with an acoustic lens, and computed tomography with unfocused transducers, are introduced. Special emphasis is placed on computed tomography, including reconstruction algorithms, spatial resolution, and related recent experiments. Promising biomedical applications are discussed throughout the text, including (1) tomographic imaging of the skin and other superficial organs by laser-induced photoacoustic microscopy, which offers the critical advantages, over current high-resolution optical imaging modalities, of deeper imaging depth and higher absorption contrasts, (2) breast cancer detection by near-infrared light or radio-frequency–wave-induced photoacoustic imaging, which has important potential for early detection, and (3) small animal imaging by laser-induced photoacoustic imaging, which measures unique optical absorption contrasts related to important biochemical information and provides better resolution in deep tissues than optical imaging.
Show PACS
87.63.L- Visual imaging
87.63.D- Ultrasonography
87.63.Hg Thermography
87.57.N- Image analysis
87.57.C- Image quality
42.62.Be Biological and medical applications

Femtosecond pulse shaping using spatial light modulators

A. M. Weiner

Rev. Sci. Instrum. 71, 1929 (2000); http://dx.doi.org/10.1063/1.1150614 (32 pages)

Full Text: | Download PDF

Show Abstract
We review the field of femtosecond pulse shaping, in which Fourier synthesis methods are used to generate nearly arbitrarily shaped ultrafast optical wave forms according to user specification. An emphasis is placed on programmable pulse shaping methods based on the use of spatial light modulators. After outlining the fundamental principles of pulse shaping, we then present a detailed discussion of pulse shaping using several different types of spatial light modulators. Finally, new research directions in pulse shaping, and applications of pulse shaping to optical communications, biomedical optical imaging, high power laser amplifiers, quantum control, and laser-electron beam interactions are reviewed. © 2000 American Institute of Physics.
Show PACS
42.65.Re Ultrafast processes; optical pulse generation and pulse compression
42.79.Hp Optical processors, correlators, and modulators
01.30.Rr Surveys and tutorial papers; resource letters
42.60.Fc Modulation, tuning, and mode locking

Absolute optical extinction measurements of single nano-objects by spatial modulation spectroscopy using a white lamp

Pierre Billaud, Salem Marhaba, Nadia Grillet, Emmanuel Cottancin, Christophe Bonnet, Jean Lermé, Jean-Louis Vialle, Michel Broyer, and Michel Pellarin

Rev. Sci. Instrum. 81, 043101 (2010); http://dx.doi.org/10.1063/1.3340875 (12 pages)

Online Publication Date: 7 April 2010

Full Text: Read Online (HTML) | Download PDF

Show Abstract
This article describes a high sensitivity spectrophotometer designed to detect the overall extinction of light by a single nanoparticle (NP) in the 10−4–10−5 relative range, using a transmission measurement configuration. We focus here on the simple and low cost scheme where a white lamp is used as a light source, permitting easy and broadband extinction measurements (300–900 nm). Using a microscope, in a confocal geometry, an increased sensitivity is reached thanks to a modulation of the NP position under the light spot combined with lock-in detection. Moreover, it is shown that this technique gives access to the absolute extinction cross-sections of the single NP provided that the incident electromagnetic field distribution experienced by the NP is accurately characterized. In this respect, an experimental procedure to characterize the light spot profile in the focal plane, using a reference NP as a probe, is also laid out. The validity of this approach is discussed and confirmed by comparing experimental intensity distributions to theoretical calculations taking into account the vector character of the tightly focused beam. The calibration procedure permitting to obtain the absolute extinction cross-section of the probed NP is then fully described. Finally, the force of the present technique is illustrated through selected examples concerning spherical and slightly elongated gold and silver NPs. Absolute extinction measurements are found to be in good consistency with the NP size and shape independently obtained from transmission electron microscopy, showing that spatial modulation spectroscopy is a powerful tool to get an optical fingerprint of the NP.
Show PACS
42.62.Fi Laser spectroscopy
07.60.-j Optical instruments and equipment
61.46.Df Structure of nanocrystals and nanoparticles ("colloidal" quantum dots but not gate-isolated embedded quantum dots)

Calibration of atomic‐force microscope tips

Jeffrey L. Hutter and John Bechhoefer

Rev. Sci. Instrum. 64, 1868 (1993); http://dx.doi.org/10.1063/1.1143970 (6 pages)

Full Text: | Download PDF

Show Abstract
Images and force measurements taken by an atomic‐force microscope (AFM) depend greatly on the properties of the spring and tip used to probe the sample’s surface. In this article, we describe a simple, nondestructive procedure for measuring the force constant, resonant frequency, and quality factor of an AFM cantilever spring and the effective radius of curvature of an AFM tip. Our procedure uses the AFM itself and does not require additional equipment.
Show PACS
68.37.Ef Scanning tunneling microscopy (including chemistry induced with STM)
68.37.Ps Atomic force microscopy (AFM)
68.37.Rt Magnetic force microscopy (MFM)
68.37.Uv Near-field scanning microscopy and spectroscopy
87.64.Dz Scanning tunneling and atomic force microscopy

A scanning tunneling microscope for a dilution refrigerator

M. Marz, G. Goll, and H. v. Löhneysen

Rev. Sci. Instrum. 81, 045102 (2010); http://dx.doi.org/10.1063/1.3328059 (7 pages)

Online Publication Date: 9 April 2010

Full Text: Read Online (HTML) | Download PDF

Show Abstract
We present the main features of a home-built scanning tunneling microscope that has been attached to the mixing chamber of a dilution refrigerator. It allows scanning tunneling microscopy and spectroscopy measurements down to the base temperature of the cryostat, T ≈ 30 mK, and in applied magnetic fields up to 13 T. The topography of both highly ordered pyrolytic graphite and the dichalcogenide superconductor NbSe2 has been imaged with atomic resolution down to T ≈ 50 mK as determined from a resistance thermometer adjacent to the sample. As a test for a successful operation in magnetic fields, the flux-line lattice of superconducting NbSe2 in low magnetic fields has been studied. The lattice constant of the Abrikosov lattice shows the expected field dependence ∝1/math and measurements in the scanning tunneling spectroscopy mode clearly show the superconductive density of states with Andreev bound states in the vortex core.
Show PACS
07.79.Cz Scanning tunneling microscopes
07.20.Mc Cryogenics; refrigerators, low-temperature detectors, and other low-temperature equipment
68.37.Ef Scanning tunneling microscopy (including chemistry induced with STM)

Three-electrode self-actuating self-sensing quartz cantilever: Design, analysis, and experimental verification

C. Julian Chen, Alex Schwarz, Roland Wiesendanger, Oliver Horn, and Jörg Müller

Rev. Sci. Instrum. 81, 053702 (2010); http://dx.doi.org/10.1063/1.3407507 (7 pages)

Online Publication Date: 13 May 2010

Full Text: Read Online (HTML) | Download PDF

Show Abstract
We present a novel quartz cantilever for frequency-modulation atomic force microscopy (FM-AFM) which has three electrodes: an actuating electrode, a sensing electrode, and a ground electrode. By applying an ac signal on the actuating electrode, the cantilever is set to vibrate. If the frequency of actuation voltage closely matches one of the characteristic frequencies of the cantilever, a sharp resonance should be observed. The vibration of the cantilever in turn generates a current on the sensing electrode. The arrangement of the electrodes is such that the cross-talk capacitance between the actuating electrode and the sensing electrode is less than 10−16 F, thus the direct coupling is negligible. To verify the principle, a number of samples were made. Direct measurements with a Nanosurf easyPPL controller and detector showed that for each cantilever, one or more vibrational modes can be excited and detected. Using classical theory of elasticity, it is shown that such novel cantilevers with proper dimensions can provide optimized performance and sensitivity in FM-AFM with very simple electronics.
Show PACS
82.45.Fk Electrodes
68.37.Ps Atomic force microscopy (AFM)
63.50.-x Vibrational states in disordered systems
81.40.Jj Elasticity and anelasticity, stress-strain relations
62.20.D- Elasticity

Photometer for monitoring the thickness of inkjet printed films for organic electronic and sensor applications

Jisun Im, Sandip K. Sengupta, and James E. Whitten

Rev. Sci. Instrum. 81, 034103 (2010); http://dx.doi.org/10.1063/1.3368638 (6 pages)

Online Publication Date: 30 March 2010

Full Text: Read Online (HTML) | Download PDF

Show Abstract
Inkjet printed organic thin films are being used for a variety of electronic and sensor applications with advantages that include ease of fabrication and reproducibility. Construction and use of a low-cost photometer based on a light-emitting diode (LED) light source and a photodiode detector are described. The photometer attaches to the exit of the printer with the transparent substrate onto which the film is printed passing between the LED and photodiode. By measuring the output voltage of the detector, the transmittance and absorbance of the inkjet printed film can be calculated in real-time. Since absorbance is linearly proportional to thickness in the Beer–Lambert regime, the thickness of the film may be monitored and controlled by varying the number of passes through the printer. Use of the photometer is demonstrated for inkjet printed films of monolayer-protected colloidal gold nanoparticles that function as chemical vapor sensors. The photometer may find applications in both research and quality control related to the manufacture of organic electronic devices and sensors and enables “feedback-controlled” inkjet printing.
Show PACS
68.60.-p Physical properties of thin films, nonelectronic
07.60.Dq Photometers, radiometers, and colorimeters
81.15.Lm Liquid phase epitaxy; deposition from liquid phases (melts, solutions, and surface layers on liquids)
82.80.-d Chemical analysis and related physical methods of analysis