Top 20 Most Read Articles
October 2011
The 20 articles with the most full-text downloads during the month, in descending order.
|
|
Rev. Sci. Instrum. 82, 091301 (2011); http://dx.doi.org/10.1063/1.3637460 (24 pages) Online Publication Date: 29 September 2011
Full Text:
Read Online (HTML)
|
Download PDF
|
|||||||||||
|
Show Abstract
The Atacama pathfinder experiment Sunyaev-Zel'dovich (APEX-SZ) instrument is a millimeter-wave cryogenic receiver designed to observe galaxy clusters via the Sunyaev-Zel'dovich effect from the 12 m APEX telescope on the Atacama plateau in Chile. The receiver contains a focal plane of 280 superconducting transition-edge sensor (TES) bolometers instrumented with a frequency-domain multiplexed readout system. The bolometers are cooled to 280 mK via a three-stage helium sorption refrigerator and a mechanical pulse-tube cooler. Three warm mirrors, two 4 K lenses, and a horn array couple the TES bolometers to the telescope. APEX-SZ observes in a single frequency band at 150 GHz with 1′ angular resolution and a 22′ field-of-view, all well suited for cluster mapping. The APEX-SZ receiver has played a key role in the introduction of several new technologies including TES bolometers, the frequency-domain multiplexed readout, and the use of a pulse-tube cooler with bolometers. As a result of these new technologies, the instrument has a higher instantaneous sensitivity and covers a larger field-of-view than earlier generations of Sunyaev-Zel'dovich instruments. The TES bolometers have a median sensitivity of 890 μK CMB
(NEy of 3.5 × 10−4 ). We have also demonstrated upgraded detectors with improved sensitivity of 530 μK CMB (NEy of 2.2 × 10−4 ). Since its commissioning in April 2007, APEX-SZ has been used to map 48 clusters. We describe the design of the receiver and its performance when installed on the APEX telescope. |
||||||||||||
|
Show PACS
|
||||||||||||
|
|
WSXM: A software for scanning probe microscopy and a tool for nanotechnology Rev. Sci. Instrum. 78, 013705 (2007); http://dx.doi.org/10.1063/1.2432410 (8 pages) Online Publication Date: 31 January 2007
Full Text:
Read Online (HTML)
|
Download PDF
|
|||
|
Show Abstract
In this work we briefly describe the most relevant features of WSXM, a freeware scanning probe microscopy software based on MS-Windows. The article is structured in three different sections: The introduction is a perspective on the importance of software on scanning probe microscopy. The second section is devoted to describe the general structure of the application; in this section the capabilities of WSXM to read third party files are stressed. Finally, a detailed discussion of some relevant procedures of the software is carried out.
|
||||
|
Show PACS
|
||||
|
|
Invited Review Article: Single-photon sources and detectors Rev. Sci. Instrum. 82, 071101 (2011); http://dx.doi.org/10.1063/1.3610677 (25 pages) Online Publication Date: 27 July 2011
Full Text:
Read Online (HTML)
|
Download PDF
|
||
|
Show Abstract
We review the current status of single-photon-source and single-photon-detector technologies operating at wavelengths from the ultraviolet to the infrared. We discuss applications of these technologies to quantum communication, a field currently driving much of the development of single-photon sources and detectors.
|
|||
|
Show PACS
|
|||
|
|
Rev. Sci. Instrum. 82, 093104 (2011); http://dx.doi.org/10.1063/1.3633947 (8 pages) Online Publication Date: 12 September 2011
Full Text:
Read Online (HTML)
|
Download PDF
|
||
|
Show Abstract
We present the x-ray optical design of the soft x-ray materials science instrument at the Linac Coherent Light Source, consisting of a varied line-spaced grating monochromator and Kirkpatrick-Baez refocusing optics. Results from the commissioning of the monochromator are shown. A resolving power of 3000 was achieved, which is within a factor of two of the design goal. |
|||
|
Show PACS
|
|||
|
|
Rev. Sci. Instrum. 82, 103702 (2011); http://dx.doi.org/10.1063/1.3646468 (8 pages) Online Publication Date: 6 October 2011
Full Text:
Read Online (HTML)
|
Download PDF
|
||
|
Show Abstract
We designed a scanning tunneling microscope working at sub-Kelvin temperatures in ultrahigh vacuum (UHV) in order to study the magnetic properties on the nanoscale. An entirely homebuilt three-stage cryostat is used to cool down the microscope head. The first stage is cooled with liquid nitrogen, the second stage with liquid 4He. The third stage uses a closed-cycle Joule-Thomson refrigerator of a cooling power of 1 mW. A base temperature of 930 mK at the microscope head was achieved using expansion of 4He, which can be reduced to ≈400 mK when using 3He. The cryostat has a low liquid helium consumption of only 38 ml/h and standing times of up to 280 h. The fast cooling down of the samples (3 h) guarantees high sample throughput. Test experiments with a superconducting tip show a high energy resolution of 0.3 meV when performing scanning tunneling spectroscopy. The vertical stability of the tunnel junction is well below 1 pm (peak to peak) and the electric noise floor of tunneling current is about 6fA/
. Atomic resolution with a tunneling current of 1 pA and 1 mV was achieved on Au(111). The lateral drift of the microscope at stable temperature is below 20 pm/h. A superconducting spilt-coil magnet allows to apply an out-of-plane magnetic field of up to 3 T at the sample surface. The flux vortices of a Nb(110) sample were clearly resolved in a map of differential conductance at 1.1 K and a magnetic field of 0.21 T. The setup is designed for in situ preparation of tip and samples under UHV condition. |
|||
|
Show PACS
|
|||
|
|
A sample holder for soft x-ray absorption spectroscopy of liquids in transmission mode Rev. Sci. Instrum. 82, 103101 (2011); http://dx.doi.org/10.1063/1.3644192 (10 pages) Online Publication Date: 4 October 2011
Full Text:
Read Online (HTML)
|
Download PDF
|
||
|
Show Abstract
A novel sample holder for soft x-ray absorption spectroscopy of liquids in transmission mode based on sample cells with x-ray transparent silicon nitride membranes is introduced. The sample holder allows for a reliable preparation of ultrathin liquid films with an adjustable thickness in the nm–μm range. This enables measurements of high quality x-ray absorption spectra of liquids in transmission mode, as will be shown for the example of liquid H2O, aqueous solutions of 3d-transition metal ions and alcohol-water mixtures. The fine structure of the x-ray absorption spectra is not affected by the sample thickness. No effects of the silicon nitride membranes were observed in the spectra. It is shown how an inhomogeneous thickness of the sample affects the spectra and how this can be avoided.
|
|||
|
Show PACS
|
|||
|
|
Rev. Sci. Instrum. 82, 093504 (2011); http://dx.doi.org/10.1063/1.3638463 (7 pages) Online Publication Date: 20 September 2011
Full Text:
Read Online (HTML)
|
Download PDF
|
||
|
Show Abstract
Neutron penumbral imaging is a significant diagnostic technique in laser-driven inertial confinement fusion experiment. It is very important to develop a new reconstruction method to improve the resolution of neutron penumbral imaging. A new nonlinear reconstruction method based on total variation (TV) regularization is proposed in this paper. A TV-norm is used as regularized term to construct a smoothing functional for penumbral image reconstruction in the new method, in this way, the problem of penumbral image reconstruction is transformed to the problem of a functional minimization. In addition, a fixed point iteration scheme is introduced to solve the problem of functional minimization. The numerical experimental results show that, compared to linear reconstruction method based on Wiener filter, the TV regularized nonlinear reconstruction method is beneficial to improve the quality of reconstructed image with better performance of noise smoothing and edge preserving. Meanwhile, it can also obtain the spatial resolution with 5 μm which is higher than the Wiener method. |
|||
|
Show PACS
|
|||
|
|
Rev. Sci. Instrum. 82, 094301 (2011); http://dx.doi.org/10.1063/1.3636077 (8 pages) Online Publication Date: 16 September 2011
Full Text:
Read Online (HTML)
|
Download PDF
|
||
|
Show Abstract
Microfluidics flow-patterning has been utilized for the construction of chip-scale miniaturized DNA and protein barcode arrays. Such arrays have been used for specific clinical and fundamental investigations in which many proteins are assayed from single cells or other small sample sizes. However, flow-patterned arrays are hand-prepared, and so are impractical for broad applications. We describe an integrated robotics/microfluidics platform for the automated preparation of such arrays, and we apply it to the batch fabrication of up to eighteen chips of flow-patterned DNA barcodes. The resulting substrates are comparable in quality with hand-made arrays and exhibit excellent substrate-to-substrate consistency. We demonstrate the utility and reproducibility of robotics-patterned barcodes by utilizing two flow-patterned chips for highly parallel assays of a panel of secreted proteins from single macrophage cells. |
|||
|
Show PACS
|
|||
|
|
Rev. Sci. Instrum. 82, 081301 (2011); http://dx.doi.org/10.1063/1.3624752 (22 pages) Online Publication Date: 23 August 2011
Full Text:
Read Online (HTML)
|
Download PDF
|
||
|
Show Abstract
We have developed an efficient spectrometer capable of performing a wide variety of coherent multidimensional measurements at optical wavelengths. The two major components of the largely automated device are a spatial beam shaper which controls the beam geometry and a spatiotemporal pulse shaper which controls the temporal waveform of the femtosecond pulse in each beam. We describe how to construct, calibrate, and operate the device, and we discuss its limitations. We use the exciton states of a semiconductor nanostructure as a working example. A series of complex multidimensional spectra—displayed in amplitude and real parts—reveals increasingly intricate correlations among the excitons.
|
|||
|
Show PACS
|
|||
|
|
Femtosecond pulse shaping using spatial light modulators Rev. Sci. Instrum. 71, 1929 (2000); http://dx.doi.org/10.1063/1.1150614 (32 pages)
Full Text:
|
Download PDF
|
||
|
Show Abstract
We review the field of femtosecond pulse shaping, in which Fourier synthesis methods are used to generate nearly arbitrarily shaped ultrafast optical wave forms according to user specification. An emphasis is placed on programmable pulse shaping methods based on the use of spatial light modulators. After outlining the fundamental principles of pulse shaping, we then present a detailed discussion of pulse shaping using several different types of spatial light modulators. Finally, new research directions in pulse shaping, and applications of pulse shaping to optical communications, biomedical optical imaging, high power laser amplifiers, quantum control, and laser-electron beam interactions are reviewed. © 2000 American Institute of Physics. |
|||
|
Show PACS
|
|||
|
|
Rev. Sci. Instrum. 82, 103103 (2011); http://dx.doi.org/10.1063/1.3646477 (6 pages) Online Publication Date: 7 October 2011
Full Text:
Read Online (HTML)
|
Download PDF
|
||
|
Show Abstract
We present a locking circuit for external cavity diode lasers implemented on a field-programmable gate array (FPGA). The main advantages over traditional non-FPGA-based locking circuits are rapid reconfigurability without any soldering and a friendly user interface. We characterize the lock quality by measuring the linewidth of a locked laser using electromagnetically induced transparency in a Rb vapor cell.
|
|||
|
Show PACS
|
|||
|
|
Rev. Sci. Instrum. 78, 031101 (2007); http://dx.doi.org/10.1063/1.2709758 (20 pages) Online Publication Date: 30 March 2007
Full Text:
Read Online (HTML)
|
Download PDF
|
||
|
Show Abstract
The technique of atom probe tomography (APT) is reviewed with an emphasis on illustrating what is possible with the technique both now and in the future. APT delivers the highest spatial resolution (sub-0.3-nm) three-dimensional compositional information of any microscopy technique. Recently, APT has changed dramatically with new hardware configurations that greatly simplify the technique and improve the rate of data acquisition. In addition, new methods have been developed to fabricate suitable specimens from new classes of materials. Applications of APT have expanded from structural metals and alloys to thin multilayer films on planar substrates, dielectric films, semiconducting structures and devices, and ceramic materials. This trend toward a broader range of materials and applications is likely to continue.
|
|||
|
Show PACS
|
|||
|
|
Invited Review Article: Interferometric gravity wave detectors Rev. Sci. Instrum. 82, 101101 (2011); http://dx.doi.org/10.1063/1.3652857 (44 pages) Online Publication Date: 25 October 2011
Full Text:
Read Online (HTML)
|
Download PDF
|
||
|
Show Abstract
A direct detection of gravitational waves is still lacking today. A network of several earthbound interferometric detectors is currently operating with a continuously improving sensitivity. The window of interest for observation has a lower cut off in the frequency domain below some tens of hertz, determined by the effect of seismic motion. For larger frequencies, the sensitivity is limited by thermal effects below few hundreds of hertz and by the quantum nature of light above that value. Each of these sources of noise pose a big technological challenge to experimentalists, and there are big expectations for the next generation of detectors. A reduction of thermal effects by at least one order of magnitude will be obtained with new and carefully designed materials. At that point the quantum nature of light will become an issue, and the use of quantum non-demolition techniques will become mandatory. In this review, we discuss interferometric detection of gravitational waves from an instrumental point of view. We try to address conceptually important issues with an audience of non-experts in mind. A particular emphasis is given to the description of the current limitations and to the perspectives of beating them.
|
|||
|
Show PACS
|
|||
|
|
A portable fluorescence detector for fast ultra trace detection of explosive vapors Rev. Sci. Instrum. 82, 103102 (2011); http://dx.doi.org/10.1063/1.3642661 (8 pages) Online Publication Date: 4 October 2011
Full Text:
Read Online (HTML)
|
Download PDF
|
||
|
Show Abstract
This paper developed a portable detector based on a specific material-based fluorescent sensing film for an ultra trace detection of explosives, such as 2,4,6-trinitrotoluene (TNT) or its derivate 2,4-dinitrotoluene (DNT), in ambient air or on objects tainted by explosives. The fluorescent sensing films are based on single-layer chemistry and the signal amplification effect of conjugated polymers, which exhibited higher sensitivity and shorter response time to TNT or DNT at their vapor pressures. Due to application of the light emitting diode and the solid state photomultiplier and the cross-correlation-based circuit design technology, the device has the advantages of low-power, low-cost, small size, and an improved signal to noise ratio. The results of the experiments showed that the detector can real-time detect and identify of explosive vapors at extremely low levels; it is suitable for the identification of suspect luggage, forensic analyses, or battlefields clearing. |
|||
|
Show PACS
|
|||
|
|
Thermal conductivity measurement from 30 to 750 K: the 3ω method Rev. Sci. Instrum. 61, 802 (1990); http://dx.doi.org/10.1063/1.1141498 (7 pages)
Full Text:
|
Download PDF
|
||
|
Show Abstract
An ac technique for measuring the thermal conductivity of dielectric solids between 30 and 750 K is described. This technique, the 3ω method, can be applied to bulk amorphous solids and crystals as well as amorphous films tens of microns thick. Errors from black‐body radiation are calculated to be less than 2% even at 1000 K. Data for a‐SiO2, Pyrex 7740, and Pyroceram 9606 are compared to results obtained by conventional techniques. |
|||
|
Show PACS
|
|||
|
|
Field programmable gate array based reconfigurable scanning probe/optical microscope Rev. Sci. Instrum. 82, 103701 (2011); http://dx.doi.org/10.1063/1.3643770 (9 pages) Online Publication Date: 3 October 2011
Full Text:
Read Online (HTML)
|
Download PDF
|
||
|
Show Abstract
The increasing popularity of nanometrology and nanospectroscopy has pushed researchers to develop complex new analytical systems. This paper describes the development of a platform on which to build a microscopy tool that will allow for flexibility of customization to suit research needs. The novelty of the described system lies in its versatility of capabilities. So far, one version of this microscope has allowed for successful near-field and far-field fluorescence imaging with single molecule detection sensitivity. This system is easily adapted for reflection, polarization (Kerr magneto-optical (MO)), Raman, super-resolution techniques, and other novel scanning probe imaging and spectroscopic designs. While collecting a variety of forms of optical images, the system can simultaneously monitor topographic information of a sample with an integrated tuning fork based shear force system. The instrument has the ability to image at room temperature and atmospheric pressure or under liquid. The core of the design is a field programmable gate array (FPGA) data acquisition card and a single, low cost computer to control the microscope with analog control circuitry using off-the-shelf available components. A detailed description of electronics, mechanical requirements, and software algorithms as well as examples of some different forms of the microscope developed so far are discussed. |
|||
|
Show PACS
|
|||
|
|
Photoacoustic imaging in biomedicine Rev. Sci. Instrum. 77, 041101 (2006); http://dx.doi.org/10.1063/1.2195024 (22 pages) Online Publication Date: 17 April 2006
Full Text:
Read Online (HTML)
|
Download PDF
|
||
|
Show Abstract
Photoacoustic imaging (also called optoacoustic or thermoacoustic imaging) has the potential to image animal or human organs, such as the breast and the brain, with simultaneous high contrast and high spatial resolution. This article provides an overview of the rapidly expanding field of photoacoustic imaging for biomedical applications. Imaging techniques, including depth profiling in layered media, scanning tomography with focused ultrasonic transducers, image forming with an acoustic lens, and computed tomography with unfocused transducers, are introduced. Special emphasis is placed on computed tomography, including reconstruction algorithms, spatial resolution, and related recent experiments. Promising biomedical applications are discussed throughout the text, including (1) tomographic imaging of the skin and other superficial organs by laser-induced photoacoustic microscopy, which offers the critical advantages, over current high-resolution optical imaging modalities, of deeper imaging depth and higher absorption contrasts, (2) breast cancer detection by near-infrared light or radio-frequency–wave-induced photoacoustic imaging, which has important potential for early detection, and (3) small animal imaging by laser-induced photoacoustic imaging, which measures unique optical absorption contrasts related to important biochemical information and provides better resolution in deep tissues than optical imaging.
|
|||
|
Show PACS
|
|||
|
|
Rev. Sci. Instrum. 75, 2787 (2004); http://dx.doi.org/10.1063/1.1785844 (23 pages) Online Publication Date: 2 September 2004
Full Text:
|
Download PDF
|
||
|
Show Abstract
Since their invention just over 20 years ago, optical traps have emerged as a powerful tool with broad-reaching applications in biology and physics. Capabilities have evolved from simple manipulation to the application of calibrated forces on—and the measurement of nanometer-level displacements of—optically trapped objects. We review progress in the development of optical trapping apparatus, including instrument design considerations, position detection schemes and calibration techniques, with an emphasis on recent advances. We conclude with a brief summary of innovative optical trapping configurations and applications. |
|||
|
Show PACS
|
|||
|
|
Atomic force microscopy at ambient and liquid conditions with stiff sensors and small amplitudes Rev. Sci. Instrum. 82, 093703 (2011); http://dx.doi.org/10.1063/1.3633950 (6 pages) Online Publication Date: 12 September 2011
Full Text:
Read Online (HTML)
|
Download PDF
|
||
|
Show Abstract
We report on atomic force microscopy (AFM) in ambient and liquid environments with the qPlus sensor, a force sensor based on a quartz tuning fork with an all-electrical deflection measurement scheme. Small amplitudes, stiff sensors with bulk diamond tips and high Q values in air and liquid allow to obtain high resolution images. The noise sources in air and liquid are analyzed and compared for standard silicon cantilevers and qPlus sensors. First, epitaxial graphene was imaged in air, showing atomic steps with 3 Å height and ridges. As a second sample system, measurements on calcite (CaCO3) in liquids were performed in water and polyethylenglycol (PEG). We demonstrate high resolution images of steps in PEG on calcite and nanolithography processes, in particular with frequency-modulation AFM the controlled dissolution of calcite monolayers.
|
|||
|
Show PACS
|
|||
|
|
Calibration of rectangular atomic force microscope cantilevers Rev. Sci. Instrum. 70, 3967 (1999); http://dx.doi.org/10.1063/1.1150021 (3 pages)
Full Text:
|
Download PDF
|
||
|
Show Abstract
A method to determine the spring constant of a rectangular atomic force microscope cantilever is proposed that relies solely on the measurement of the resonant frequency and quality factor of the cantilever in fluid (typically air), and knowledge of its plan view dimensions. This method gives very good accuracy and improves upon the previous formulation by Sader et al. [Rev. Sci. Instrum. 66, 3789 (1995)] which, unlike the present method, requires knowledge of both the cantilever density and thickness. © 1999 American Institute of Physics. |
|||
|
Show PACS
|
|||